RCM 150/300

The RCM Series converters are reliable power supplies for railway and transportation systems. There are 2 input voltage ranges covering all common railway batteries. The output delivers 150 or 300 W at 12 or 24 V. The converters are designed for chassis mounting and exhibit a closed housing. Many options are available, such as an output ORing FET for redundant operation, output voltage adjustment, interruption time of 10 ms (class ST2), shutdown input, and an output voltage monitor controlling a relay (change-over contact).

Specifications

  • 2 ranges, covering all railway batteries
  • 2 output voltages,12 and 24 V
  • 3 connectors: Input, output, auxiliary
  • Compliant to EN 50155, EN 50121-3-2
  • Protected against fire and smoke according to EN 45545

Features

  • RoHS lead-free-solder product
  • Closed housing for chassis mounting
  • Extremely high efficiency and high power density
  • Low inrush current

Email Form

The RCM Series converters are reliable power supplies for railway and transportation systems. There are 2 input voltage ranges covering all common railway batteries. The output delivers 150 or 300 W at 12 or 24 V. The converters are designed for chassis mounting and exhibit a closed housing. Many options are available, such as an output ORing FET for redundant operation, output voltage adjustment, interruption time of 10 ms (class ST2), shutdown input, and an output voltage monitor controlling a relay (change-over contact).

Specifications

  • 2 ranges, covering all railway batteries
  • 2 output voltages,12 and 24 V
  • 3 connectors: Input, output, auxiliary
  • Compliant to EN 50155, EN 50121-3-2
  • Protected against fire and smoke according to EN 45545

Features

  • RoHS lead-free-solder product
  • Closed housing for chassis mounting
  • Extremely high efficiency and high power density
  • Low inrush current

Email Form

* These fields are required.

RCM 150/300

Part Number Distributor Stock Drawing Data Sheet Power (W) Output Voltage (VDC) Output Current (A) Voltage Input (VDC) Operating Temperature (ºC) Isolation Dimension Auxiliary functions and options
110RCM150-24DMQ check_circle     150 24 6.25 43.2-154 -40 to 70 Isolated 164.5 x 96 x 36.1 Out OK, output voltage adjust, shutdown, Interruption time, ORing FET
110RCM150-24DF check_circle     150 24 6.25 43.2-154 -40 to 70 Isolated 164.5 x 96 x 36.1 Out OK, output voltage adjust, shutdown, Fuse
110RCM150-24D check_circle     150 24 6.25 43.2-154 -40 to 70 Isolated 164.5 x 96 x 36.1 Out OK, output voltage adjust, shutdown
110RCM150-12D check_circle     150 12 12.5 43.2-154 -40 to 70 Isolated 164.5 x 96 x 36.1 Out OK, output voltage adjust, shutdown
24RCM300-24 check_circle     300 24 12.5 14.4-50.4 -40 to 70 Isolated 188.6 x 116 x 38
110RCM300-12DMQ check_circle     300 12 25 43.2-154 -40 to 70 Isolated 188.6 x 116 x 38 Out OK, output voltage adjust, shutdown, Interruption time, ORing FET
110RCM300-12DMQF check_circle     300 12 25 43.2-154 -40 to 70 Isolated 188.6 x 116 x 38 Out OK, output voltage adjust, shutdown, Interruption time, ORing FET, Fuse
110RCM150-12DMQF check_circle     150 12 12.5 43.2-154 -40 to 70 Isolated 164.5 x 96 x 36.1 Out OK, output voltage adjust, shutdown, Interruption time, ORing FET, Fuse
110RCM300-24DMQF check_circle     300 24 12.5 43.2-154 -40 to 70 Isolated 188.6 x 116 x 38 Out OK, output voltage adjust, shutdown, Interruption time, ORing FET, Fuse
24RCM150-12 check_circle     150 12 12.5 14.4-50.4 -40 to 70 Isolated 164.5 x 96 x 36.1
24RCM150-24D check_circle     150 24 6.25 14.4-50.4 -40 to 70 Isolated 164.5 x 96 x 36.1 Out OK, output voltage adjust, shutdown
24RCM150-24DMQF check_circle     150 24 6.25 14.4-50.4 -40 to 70 Isolated 164.5 x 96 x 36.1 Out OK, output voltage adjust, shutdown, Interruption time, ORing FET, Fuse
110RCM150-12 check_circle     150 12 12.5 43.2-154 -40 to 70 Isolated 164.5 x 96 x 36.1
24RCM150-24 check_circle     150 24 6.25 14.4-50.4 -40 to 70 Isolated 164.5 x 96 x 36.1
110RCM300-12 check_circle     300 12 25 43.2-154 -40 to 70 Isolated 188.6 x 116 x 38
24RCM300-12 check_circle     300 12 25 14.4-50.4 -40 to 70 Isolated 188.6 x 116 x 38
110RCM300-24 check_circle     300 24 12.5 43.2-154 -40 to 70 Isolated 188.6 x 116 x 38
110RCM150-24 check_circle     150 24 6.25 43.2-154 -40 to 70 Isolated 164.5 x 96 x 36.1
24RCM300-24D check_circle     300 24 12.5 14.4-50.4 -40 to 70 Isolated 188.6 x 116 x 38 Out OK, output voltage adjust, shutdown

Filters

Clear All
Tech Help  
Please fill in below and send.

{{result}}

Tech Help